Design Capacity: 1,800,000 t/y cement Design Capacity: 2 x 3,200 t/d clinker
Main steps of the rehabilitation work
- Erection of a captive power plant
- Planning of future quarry operation
- Upgrade of the raw mill and kiln electrostatic precipitators
- Modification of preheater, kiln inlet and outlet sealing
- Modification of all installed bag filters to jet-pulse type
- Installation of several new bag filters in order to reduce dust emissions
- Installation of several new frequency controlled AC drives for process machinery with variable speed
- Installation of new ID fans
- Upgrade of clinker coolers including electrostatic precipitators and clean gas fans
- Installation of new motors for all eight ball mills
|
|
Scope of AUSTROPLAN
- Fact-finding mission / site investigation
- Evaluation and verification of the data received
- Preparation of the tender documentation for the rehabilitation project
- Evaluation of offers
- Assistance to the client during negotiations
- Site Services
Financing: by Owner |